High resolution CCD spectrograph
페이스북 공유하기 트위터 공유하기 아웃룩 공유하기
  • High resolution CCD spectrograph
  • High resolution CCD spectrograph
마일리지 판매가의 1%
제조사(브랜드) Mightex Systems
판매사/수입사 유니나노텍(주) UniNanoTech Co., Ltd.
납기일 2주 이내
배송비 기본 배송료 3,500원(배송방법에 따라 배송비가 달라집니다)
배송정보 10만원 이상 구매시 기본택배 배송료 무료
주문안내 최소 주문 가능 금액 : 3만원
제품 사양서 인쇄
Cat. No. 모델명 제품명 사양 판매단위 판매가 수량
25-00193-01 HRS-NIR-025 High resolution NIR CCD spectrograph 600-1000nm NIR 1ea/pk 3,404,500원
- +
25-00193-02 HRS-VIS-025 High resolution VIS CCD spectrograph 390-780nm Visible 1ea/pk 3,406,700원
- +
25-00193-03 HRS-UV1-025 High resolution UV CCD spectrograph 200-400nm UV 1ea/pk 3,406,700원
- +
25-00193-04 CAL-SPC-RRCETC Relative radiometric calibration service with exposure time linearity calibration for Mightex's spec 1ea/pk 517,000원
- +
25-00193-05 HRS-BD1-025 High-Resolution High-Stability CCD Spectrometers 300~1050nm Broad Band 1ea/pk 4,548,500원
- +
25-00193-07 HRS-BD1-xxx [Note: specify slit size by email or in note when checking out.] 300~1050nm Broad Band 1ea/pk 4,757,500원
- +
25-00193-08 HRS-NIR-xxx Note: specify slit size by email or in note when checking out.] 600-1000nm NIR 1ea/pk 3,632,200원
- +
25-00193-09 HRS-UV1-xxx [Note: specify slit size by email or in note when checking out.] 200-400nm UV 1ea/pk 3,841,200원
- +
25-00193-10 HRS-VIS-xxx [Note: specify slit size by email or in note when checking out.] 390-780nm Visible 1ea/pk 3,634,400원
- +
선택한 모델 총 0개 부가세 포함 / 0 원

High-Resolution High-Stability CCD Spectrometers (UV, VIS and NIR)

CAL-SPC-RRCETC, HRS-BD1-025, HRS-BD1-xxx, HRS-NIR-025, HRS-NIR-xxx, HRS-UV1-025, HRS-UV1-xxx, HRS-VIS-025, HRS-VIS-xxx

Compact CCD spectrometers are widely used in process control, environment monitoring, and scientific research applications. Mightex HRS series compact CCD spectrometers features a high resolution 100mm Czerny-Turner optical platform coupled with a Toshiba 3648-element CCD array. The optimized optical path yields both high spectral resolution and high light collection efficiency.

Wavelength and amplitude stability is often a critical requirement for many spectrometer applications. All optical components in the HRS series spectrometers are mounted directly on a single piece base without using screws. A box enclosure structure further increases stiffness of the base. The proprietary mounting method ensures high stability over time and temperature.

The spectrometer takes input through a SMA connector port. Usually a fiber patch cord is used to transmit light into the spectrometer. However it's also possible to send the input light directly into the spectrometer through the input slit. Input ports are interchangeable so that ports with different slit size (or without slit) can be used. Note that wavelength calibration is necessary after changing the input port.

A 16-bit DAC is used to convert the analog signal from the CCD array into a digital stream. The electronics hardware also includes trigger input and four programmable digital I/Os for interfacing with other equipment such as a light source. The spectrometer is controlled through a USB2.0 interface which also supplies all the electric power needed to operate the spectrometer.

Standard software package includes a full-featured PC software as well as a software development kit (SDK) for further software development.

APPLICATIONS

Lab research
Process control
Environment monitoring

  Click here to download Spec sheet
 
HRS Spectrometer Graphical User Interface

 
Ordering Information:
ModelName
CAL-SPC-RRCETC

Relative radiometric calibration service

with exposure time linearity calibration for Mightex's spectrometers

   
HRS-BD1-025

High-Resolution High-Stability CCD Spectrometers

(with 25 micron entrance slit), 300~1050nm Broad Band.

   
HRS-BD1-xxx

High-Resolution High-Stability CCD Spectrometers

(with custom entrance slit), 300~1050nm Broad Band.

[Note: specify slit size by email or in note when checking out.]

   
HRS-NIR-025

High-Resolution High-Stability CCD Spectrometers

 (with 25 micron entrance slit), 600-1000nm NIR

   
HRS-NIR-xxx

High-Resolution High-Stability CCD Spectrometers

(with custom entrance slit), 600-1000nm NIR.

[Note: specify slit size by email or in note when checking out.]

   
HRS-UV1-025

High-Resolution High-Stability CCD Spectrometers

(with 25 micron entrance slit), 200-400nm UV

   
HRS-UV1-xxx

High-Resolution High-Stability CCD Spectrometers

(with custom entrance slit), 200-400nm UV.

[Note: specify slit size by email or in note when checking out.]

   
HRS-VIS-025

High-Resolution High-Stability CCD Spectrometers

(with 25 micron entrance slit), 390-780nm Visible

   
HRS-VIS-xxx

High-Resolution High-Stability CCD Spectrometers

 (with custom entrance slit), 390-780nm Visible.

 [Note: specify slit size by email or in note when checking out.]

   
All prices are FOB California, unless otherwise stated.
Please call/email for volume pricing.
1. 단순변심일경우 : 물품수령 후 7일이내 반품가능(반품배송비 구매자가 부담)
2. 표시, 광고 내용과 상이하거나 물품 하자인 경우 : 물품수령 후 3개월이내, 또는 그 사실을 안날 또는 알수 있었던 날로부터 30일이내 반품가능 (반품배송비 판매자가 부담)

단, 아래의 내용인 경우에는 교환/반품/환불이 불가능하오니 참조하시기 바랍니다.

1. 반품요청기간이 지난 경우
2. 고객님의 책임있는 사유로 상품등이 멸실 또는 훼손된 경우(단 상품의 내용을 확인하기 위하여 포장 등을 훼손한 경우는 제외)
3. 주문 당시 해외 발주 상품의 경우
4. 고객의 요청으로 주문제작이 이루어진 경우
5. 포장을 개봉하였거나 포장이 훼손되어 상품의 가치가 현저하게 감소한 경우
6. 고객님의 사용 또는 일부 소비에 의하여 상품의 가치가 현저히 감소한 경우
7. 재판매가 곤란한 정도로 상품등의 가치가 현저히 감소한 경우
8. 복제가 가능한 상품 등의 포장을 훼손한 경우